COLUMN

What Is Magnetic Particle Inspection? Finding Invisible Flaws in Critical Parts

The strength of a forged part does not come from the forging process alone. Only after inspection confirms there are no hidden flaws can a part be shipped with confidence as a critical safety component. This article explains magnetic particle inspection — the method we use for quality assurance — including how it works and what it can and cannot do.

Magnetic particle inspection: revealing hidden flaws with magnetism

Magnetic particle inspection (MT, magnetic particle testing) is a non-destructive test — one that examines a part without damaging it — used on ferromagnetic materials such as steel to find flaws on or just below the surface. When the part is magnetized, a flaw disturbs the magnetic field and causes it to leak out at that spot. A liquid carrying fine magnetic particles is then applied; the particles are drawn to the leakage and gather along the flaw, making an otherwise invisible crack appear as a visible line.

Typically, fluorescent particles are used and the part is viewed under ultraviolet light in a darkened area. Because the particles build up wider than the flaw itself, under suitable conditions cracks finer than a human hair can be seen with the naked eye.

Why it suits forged parts — and where its limits are

Most of the flaws that matter in forged parts — laps, surface cracks, quench cracks from heat treatment — occur on or near the surface, which is exactly the zone where magnetic particle inspection excels. It is also relatively quick even on complex shapes, making it well suited to production parts.

Its limits: it cannot be used on non-magnetic materials (aluminum, or non-magnetic stainless steels such as SUS304), and flaws deep inside a part call for a different method such as ultrasonic testing. For reference, here is how it compares with liquid penetrant testing, which draws a colored dye into surface flaws, and ultrasonic testing, which examines the interior using reflected sound waves.

Common non-destructive tests at a glance
MethodMaterialsBest forPoints to note
Magnetic particleFerromagnetic materials such as steelSurface and near-surface flawsMagnetic materials only; no internal flaws; demagnetization needed afterwards
Liquid penetrantMetals and non-metals (except porous materials)Flaws open to the surfaceNothing below the surface; penetration takes time
UltrasonicMost metalsInternal flawsDifficult on complex shapes and small parts

After inspection: demagnetization, the essential last step

A part retains some magnetism after testing, so it is normally demagnetized before moving on. Residual magnetism can attract metal chips during later machining or interfere with the equipment the part is assembled into. Inspection is not finished until demagnetization is done.

Our inspection setup

In addition to dimensional inspection with dedicated gauges, we operate magnetic particle inspection equipment and test forged parts for flaws according to each customer’s quality requirements. This lets us confirm that no harmful surface or near-surface flaws are present before shipment, and supports our production of critical safety parts such as engine and suspension components. Whether inspection is needed, and at what rate (100% or sampling), can be decided together — please send us your drawing along with your requirements.

Back to column list

Talk to us about your forging and die needs

Integrated production from raw material to finished part. We welcome small-lot and short-lead-time inquiries, as well as die-only orders. Contact us by phone, fax, or our online form.

Phone:047-482-6331(Weekdays 8:00–17:00 (JST))